故障分析:首先觀察恒溫恒濕試驗箱制冷(leng)(leng)壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)在恒(heng)(heng)溫(wen)恒(heng)(heng)濕(shi)(shi)(shi)試(shi)(shi)驗(yan)箱試(shi)(shi)驗(yan)箱運行過(guo)程(cheng)中是(shi)否能夠(gou)啟動,如(ru)(ru)果恒(heng)(heng)溫(wen)恒(heng)(heng)濕(shi)(shi)(shi)試(shi)(shi)驗(yan)箱的(de)壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)在運行過(guo)程(cheng)中都(dou)(dou)能夠(gou)啟動,說(shuo)明從(cong)主(zhu)電(dian)源到各壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)的(de)電(dian)器線路都(dou)(dou)正(zheng)常(chang),電(dian)器系統(tong)方面(mian)也(ye)就(jiu)沒有問題。當恒(heng)(heng)溫(wen)恒(heng)(heng)濕(shi)(shi)(shi)試(shi)(shi)驗(yan)箱的(de)電(dian)氣系統(tong)都(dou)(dou)沒有問題時,則繼續檢(jian)(jian)查制冷(leng)(leng)系統(tong)。首先檢(jian)(jian)查恒(heng)(heng)溫(wen)恒(heng)(heng)濕(shi)(shi)(shi)試(shi)(shi)驗(yan)箱的(de)兩組制冷(leng)(leng)壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)組,如(ru)(ru)果低(di)溫(wen)( R23 )級(ji)壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)的(de)排氣和(he)吸(xi)(xi)氣壓(ya)(ya)(ya)力都(dou)(dou)較正(zheng)常(chang)值(zhi)偏(pian)低(di),且吸(xi)(xi)氣壓(ya)(ya)(ya)力呈抽(chou)空狀態,這就(jiu)說(shuo)明主(zhu)制冷(leng)(leng)機(ji)(ji)(ji)組的(de)制冷(leng)(leng)劑(ji)量明顯不(bu)(bu)足。再用手(shou)摸一下恒(heng)(heng)溫(wen)恒(heng)(heng)濕(shi)(shi)(shi)試(shi)(shi)驗(yan)箱的(de)主(zhu)機(ji)(ji)(ji)組R23壓(ya)(ya)(ya)縮(suo)(suo)機(ji)(ji)(ji)的(de)排氣和(he)吸(xi)(xi)氣管路,如(ru)(ru)發現排氣管路的(de)溫(wen)度不(bu)(bu)高,吸(xi)(xi)氣管路的(de)溫(wen)度也(ye)不(bu)(bu)低(di)(未結(jie)霜) , 這也(ye)說(shuo)明了(le)主(zhu)機(ji)(ji)(ji)組的(de)R23制冷(leng)(leng)劑(ji)的(de)缺乏。
恒(heng)溫(wen)(wen)(wen)(wen)恒(heng)濕試驗箱的(de)一個為主(zhu)(zhu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu),另-一個為輔(fu)助機(ji)(ji)(ji)(ji)(ji)組(zu)(zu),在(zai)降溫(wen)(wen)(wen)(wen)速率較大時(shi),兩(liang)組(zu)(zu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)同時(shi)工作(zuo)(zuo)(zuo)(zuo),在(zai)溫(wen)(wen)(wen)(wen)度保持階段(duan)初(chu)期,兩(liang)組(zu)(zu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)依然同時(shi)工作(zuo)(zuo)(zuo)(zuo)。待溫(wen)(wen)(wen)(wen)度初(chu)步穩(wen)定(ding)下來,輔(fu)助機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)就停止(zhi)工作(zuo)(zuo)(zuo)(zuo),由主(zhu)(zhu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)來維持溫(wen)(wen)(wen)(wen)度的(de)降溫(wen)(wen)(wen)(wen)及穩(wen)定(ding)。如(ru)果(guo)主(zhu)(zhu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)R23泄露(lu),會使主(zhu)(zhu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)的(de)制冷(leng)效果(guo)不大,由于降溫(wen)(wen)(wen)(wen)過程中,兩(liang)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)同時(shi)工作(zuo)(zuo)(zuo)(zuo),故(gu)沒有溫(wen)(wen)(wen)(wen)度穩(wen)定(ding)不住的(de)現(xian)象,而(er)指示降溫(wen)(wen)(wen)(wen)速率降低。在(zai)溫(wen)(wen)(wen)(wen)度保持階段(duan),一旦輔(fu)助機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)停止(zhi)工作(zuo)(zuo)(zuo)(zuo),主(zhu)(zhu)機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)又(you)無制冷(leng)作(zuo)(zuo)(zuo)(zuo)用,恒(heng)溫(wen)(wen)(wen)(wen)恒(heng)濕試驗箱內的(de)空氣溫(wen)(wen)(wen)(wen)度就會緩慢上(shang)升,當溫(wen)(wen)(wen)(wen)度上(shang)升到一定(ding)程度,控制系統就會又(you)啟動輔(fu)助機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)來降溫(wen)(wen)(wen)(wen),然后輔(fu)助機(ji)(ji)(ji)(ji)(ji)組(zu)(zu)又(you)停止(zhi)工作(zuo)(zuo)(zuo)(zuo),如(ru)此(ci)反(fan)復,便會出現(xian)低溫(wen)(wen)(wen)(wen)度保持不住的(de)故(gu)障現(xian)象。
至此,已確認恒(heng)溫恒(heng)濕(shi)試(shi)驗(yan)箱(xiang)的(de)(de)故障(zhang)原因是主制冷機(ji)(ji)組的(de)(de)低溫( R23 )級機(ji)(ji)組的(de)(de)制冷劑(ji)R23泄漏(lou)(lou)。恒(heng)溫恒(heng)濕(shi)試(shi)驗(yan)箱(xiang)維(wei)修方(fang)法:對(dui)制冷系統(tong)進行查(cha)(cha)漏(lou)(lou),用檢漏(lou)(lou)儀和肥皂水相(xiang)結(jie)合的(de)(de)方(fang)法來檢查(cha)(cha)漏(lou)(lou)點在哪(na),如(ru)果發現是熱(re)氣謗通磁閥(fa)(fa)的(de)(de)閥(fa)(fa)桿裂了有細縫,則更(geng)換此電磁閥(fa)(fa),如(ru)發現其它地方(fang)的(de)(de)泄漏(lou)(lou),則用氧焊將(jiang)泄漏(lou)(lou)處補(bu)焊完整,再對(dui)系統(tong)重新(xin)充氟,系統(tong)運行即可恢(hui)復正(zheng)常。
經上(shang)文可以看出,對恒(heng)溫恒(heng)濕(shi)試驗(yan)箱低溫度保持不住的(de)(de)(de)故(gu)障(zhang)現象,分析和(he)判(pan)斷(duan)(duan)基本上(shang)是從(cong)易(yi)到難,先外后里(li),先電(dian)氣詬(gou)冷氣的(de)(de)(de)方式進行(xing)分析和(he)判(pan)斷(duan)(duan),熟悉和(he)了(le)解(jie)恒(heng)溫恒(heng)濕(shi)試驗(yan)箱的(de)(de)(de)原理和(he)工(gong)作(zuo)過(guo)程則是分析故(gu)障(zhang)判(pan)斷(duan)(duan)故(gu)障(zhang)的(de)(de)(de)基礎。只有深(shen)入了(le)解(jie)恒(heng)溫恒(heng)濕(shi)試驗(yan)箱的(de)(de)(de)工(gong)作(zuo)原理和(he)工(gong)作(zuo)過(guo)程,才能迅(xun)速地解(jie)決運行(xing)過(guo)程中出現的(de)(de)(de)各種(zhong)問題。